ZP2-F Series Fire Alarm Control Panel Installation Manual P/N 501-405203-1-20 • REV 2.0 • ISS 04MAR11 Copyright © 2011 UTC Fire & Security. All rights reserved. Trademarks and The ZP2-F Series name and logo are trademarks of patents UTC Fire & Security. Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products. Manufacturer UTC Fire & Security (Africa), 555 Voortrekker Road, Maitland, Cape Town 7405, PO Box 181 Maitland, South Africa. Authorized EU manufacturing representative: UTC Fire & Security B.V. Kelvinstraat 7, 6003 DH Weert, Netherlands. Version This document covers control panels with firmware version 2.0 or later. Certification European Union 1999/5/EC (R&TTE directive): Hereby, UTC Fire & Security declares directives that this device is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. 2002/96/EC (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info. 2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see: www.recyclethis.info. Contact information For contact information, see www.utcfireandsecurity.com. Content Important information ii Chapter 1 Introduction 1 Product range 2 Product compatibility 3 Control panel overview 4 Chapter 2 Installation 13 Cabinet and PCB layout 14 Cabinet installation 16 Connections 18 Chapter 3 Configuration and commissioning 29 Introduction 30 Maintenance level operation and configuration 34 Installer level operation and configuration 48 Commissioning 85 Chapter 4 Maintenance 87 Fire alarm system maintenance 88 Battery maintenance 89 Chapter 5 Technical specifications 91 Appendix A Default configurations 99 Appendix B Menu maps 101 Appendix C Regulatory information 109 Index 111 ZP2-F Series Fire Alarm Control Panel Installation Manual i Important information Introduction This is the installation manual for the ZP2-F Series Fire Alarm Control Panels. Read these instructions and all related documentation entirely before installing or operating this product. Firmware compatibility Information in this document covers control panels with firmware version 2.0 or later. This document must not be used as a guide to installation, configuration, or operation of control panels with an earlier firmware version. To check the firmware version of your control panel, see the Revision report in the Reports menu. Limitation of liability Installation in accordance with this manual, applicable codes, and the instructions of the authority having jurisdiction is mandatory. UTC Fire & Security (UTCFS) shall not under any circumstances be liable for any incidental or consequential damages arising from loss of property or other damages or losses owing to the failure of UTCFS products beyond the cost of repair or replacement of any defective products. UTCFS reserves the right to make product improvements and change product specifications at any time. While every precaution has been taken during the preparation of this manual to ensure the accuracy of its contents, UTCFS assumes no responsibility for errors or omissions. Advisory messages Advisory messages alert you to conditions or practices that can cause unwanted results. The advisory messages used in this document are shown and described below. WARNING: Warning messages advise you of hazards that could result in injury or loss of life. They tell you which actions to take or to avoid in order to prevent the injury or loss of life. Caution: Caution messages advise you of possible equipment damage. They tell you which actions to take or to avoid in order to prevent the damage. ii ZP2-F Series Fire Alarm Control Panel Installation Manual Note: Note messages advise you of the possible loss of time or effort. They describe how to avoid the loss. Notes are also used to point out important information that you should read. ZP2-F Series Fire Alarm Control Panel Installation Manual iii iv ZP2-F Series Fire Alarm Control Panel Installation Manual Chapter 1 Introduction Summary This chapter provides an introduction to your control panel, the main controls, and the indicators. Content Product range 2 Fire alarm and repeater panels 2 Repeater functionality 2 Fire routing and fire protection control and indication 2 Product compatibility 3 Control panel overview 4 The user interface 4 Front panel controls and indicators 5 LCD controls and indicators 8 Indication of remote and local events on the LCD 10 Acoustic indicators 10 Summary of conditions 10 ZP2-F Series Fire Alarm Control Panel Installation Manual 1 Chapter 1: Introduction Product range Fire alarm and repeater panels The series includes the control panels shown below. Table 1: Fire alarm and repeater panels Model Cabinet size [1] Description ZP2-F1 Large One-loop addressable fire alarm control panel ZP2-F1-S Small ZP2-F1-FB Large One-loop addressable fire alarm control panel with fire routing and fire protection controls ZP2-F1-FB-S Small ZP2-F1-SC Large One-loop addressable fire alarm control panel with fire routing and fire protection controls [2] ZP2-F1-SC-S Small ZP2-F2 Large Two-loop addressable fire alarm control panel ZP2-F2-S Small ZP2-F2-FB Large Two-loop addressable fire alarm control panel with fire routing and fire protection controls ZP2-F2-FB-S Small ZP2-F2-SC Large Two-loop addressable fire alarm control panel with fire routing and fire protection controls [2] ZP2-F2-SC-S Small ZP2-FR Large Addressable fire alarm repeater panel ZP2-FR-S Small ZP2-FR-FB Large Addressable fire alarm repeater panel with fire routing and fire protection controls ZP2-FR-FB-S Small ZP2-FR-SC Large Addressable fire alarm repeater panel with fire routing and fire protection controls [2] ZP2-FR-SC-S Small [1] See Chapter 5 “Technical specifications” on page 91 for cabinet dimensions [2] Includes a fireman's key Repeater functionality All control panels in a fire network can be configured for repeater functionality. This includes fire alarm control panels, provided that they have a network board installed. For more information, see “Firenet configuration” on page 50. Fire routing and fire protection control and indication In this document, information on control and indication for fire routing and fire protection applies only to control panels that include those features. 2 ZP2-F Series Fire Alarm Control Panel Installation Manual Chapter 1: Introduction Product compatibility Products compatible with these control panels are listed in the supplied compatibility list. Only those products specified in the compatibility list are guaranteed to be compatible with these control panels. For further details contact your local supplier. ZP2-F Series Fire Alarm Control Panel Installation Manual 3 Chapter 1: Introduction Control panel overview This topic provides an introduction to the control panel user interface, LCD, operator controls, and indicators. The user interface Figure 1: The control panel user interface (with fire routing and fire protection controls) 1. Supply LED 13. System Fault LED 2. General Test LED 14. Low Battery LED 3. General Disable LED 15. Earth Fault LED 4. General Fault LED 16. Supply Fault LED 5. Alarm LED 17. Fire Protection Fault/Disabled/Test LED 6. LCD 18. Fire Protection Delay button and LED 7. Sounder Delay button and LED 19. Fire Protection On/Acknowledged button and LED 8. Sounder Fault/Disabled/Test LED 20. Fire Routing Fault/Disabled/Test LED 9. Jog dial and function buttons 21. Fire Routing Delay button and LED 10. Reset button and LED 22. Fire Routing On/Acknowledged button and 11. Panel Silence button and LED LED 12. Sounder Start/Stop Button and LED For a detailed overview of front panel controls and indicators, see “Front panel controls and indicators” on page 5. 4 ZP2-F Series Fire Alarm Control Panel Installation Manual
Description: