Preview Interfacing Elevators with Fire Alarm and Sprinklers

IInntteerrffaacciinngg EElleevvaattoorrss wwiitthh FFiirree AAllaarrmm aanndd SSpprriinnkklleerrss IIEEEEEE AAttllaannttaa CChhaapptteerr MMaayy 1155,, 22000066 BBrriiaann KK FFaabbeell,, PPEE Excepts provided courtesy B. Fraser, Simplex-Grinnell Corp. AAggeennddaa (cid:1) Today’s Codes (cid:2) NFPA, ASME, IBC/IFC (cid:1) Conflicts/Issues (cid:1) Tomorrow’s Codes? Excepts provided courtesy B. Fraser, Simplex-Grinnell Corp. AApppplliiccaabbllee CCooddeess NFPA 1, 13, 70, 72 IFC Building Codes Elevator & Escalator Safety IBC, NFPA 101 Code Atlanta, Georgia ASME/ANSI A17.1 Excepts provided courtesy B. Fraser, Simplex-Grinnell Corp. PPrroobblleemm!! Can’t find all the requirements in one place! Must use Codes together! Excepts provided courtesy B. Fraser, Simplex-Grinnell Corp. BBiiggggeerr PPrroobblleemm!! Codes are out of Synch! (cid:1) (cid:1) ASME A17.1 NFPA 13 & 72 (cid:2) A17.1 – 1996 (cid:2) 1996 (cid:2) A17.1a – 1997 (cid:2) 1999 (cid:2) A17.1b – 1998 (cid:2) 2002 (cid:2) A17.1c – 1999 (cid:2) A17.1d – 2000 (cid:2) 2007 (cid:2) A17.1a – 2002 (cid:2) A17.1b – 2003 (cid:2) A17.1 - 2004 Excepts provided courtesy B. Fraser, Simplex-Grinnell Corp. AASSMMEE AA1177..11 (cid:1) Safety Code for Elevators and Escalators (cid:2) Provides Operational Sequences for: • Phase 1 - Emergency Recall Operation • Power Shutdown – “Shunt Trip” Operation Excepts provided courtesy B. Fraser, Simplex-Grinnell Corp. AASSMMEE AA1177..11 (cid:1) Phase 1 - Emergency Recall Operation The Operation of an elevator wherein it is automatically or manually recalled to a specific landing and removed from normal service because of activation of firefighters’ service Excepts provided courtesy B. Fraser, Simplex-Grinnell Corp. AASSMMEE AA1177..11 (cid:1) Power Shutdown (Shunt Trip) Mainline elevator power is disconnected from the elevator to eliminate potential problems as a result of sprinkler actuation in the hoistway or elevator machine room Excepts provided courtesy B. Fraser, Simplex-Grinnell Corp. AASSMMEE AA1177..11 (cid:1) Added in 2004 (cid:1) Section 2.27 - Emergency Operation and Signaling Devices (cid:2) 2.27.3.2 – Phase 1 Emergency recall operation by fire alarm initiating devices Excepts provided courtesy B. Fraser, Simplex-Grinnell Corp. AASSMMEE AA1177..11 -- 22000044 (cid:1) Section 2.8 – Equipment in Hoistways, Machinery Spaces, Machine Room, Control Spaces and Control Rooms (cid:2) 2.8.2.3.2 • Shunt Trip/Power Disconnect Requirement Excepts provided courtesy B. Fraser, Simplex-Grinnell Corp.

Description:
NFPA 72 -2002. ➢Chapter 6 – Protected Premises. ➢6.15 Protected Premises Fire Safety Functions. 6.15.3 - Elevator Recall for Fire Fighters Service.
See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.